Never take the sample from the first concrete out of the mixer. The test is considered positive if symptoms are increased in the slumped position and decreased as the patient moves out of neck flexion. If the slump test is to determine whether or not the concrete is to be accepted, the sample must be taken from the early part of the load. Concrete slump test is carried out from batch to batch to check the uniform quality of concrete during construction. Measure the amount of slump in inches from the bottom of the straight edge to the top of the slumped concrete at a point over the original center of the base. To carry out the slump test, the fresh concrete mix was poured into a truncated cone. A concrete slump test is used to determine the correct water content in a batch of concrete. Use of the slump test over the straight leg raise test for. The mold for the concrete slump test is a frustum of a cone, 300 mm 12 in of height. The slump test is the most simple workability test for concrete, involves low cost and provides immediate results. A concrete batch with high slump is an indication that the concrete has to. Cpccco3033a slump test concrete modification history not applicable unit descriptor unit descriptor this unit of competency specifies the outcomes required to conduct a slump test to concrete to ensure the mix is workable and complies with the delivery docket and specified order.
The test is essential for a fuller recognition of the factors contributing to some patients disorders. True slump true slump is the only slump that can be measured in the test. Standard test method for slump of hydrauliccement concrete 1. A number of companies undertake specialised slump testing. Tools standard slump cone 100 mm top diameter x 200 mm bottom diameter x 300 mm high small scoop bulletnosed rod 600 mm long x 16 mm diameter rule slump plate 500 mm x 500 mm. The apparatus used for doing slump test are slump cone and tamping rod. Positionand shim the base plate so it is fully supported, flat, and level. Slump is the distance, measured in inches, the concrete settles after the slump cone is removed. About 6 liter of concrete is needed to perform the test, sampled normally.
Changes in the value of slump obtained during a job may indicate changes in. Concrete slump test generally concrete slump value is used to find the workability, which. Astm c143c143m15a standard test method for slump of. Concrete slump test to determine the workability of concrete mix. A little extra effort to observe good practice is the key to ensure that the concrete properties are properly evaluated. The slump is carried out as per procedures mentioned in astm c143 in the united. Ferraris and brower 2001 is intended for use as a field test to measure both the plastic viscosity and yield stress of concrete mixtures. Per epi info 2000, the slump test had higher levels of sensitivity and specificity compared to.
Maitlands slump test is a widely used neural tissue tension test. Describes also apparatus, procedure, expression of results, and test report. The tool typically has an internal diameter of 100 millimetres 3. Standard test method for slump of hydrauliccement concrete. Stand firmly on the footpieces and fill the volume of the cone with the sample. Slump test is used to determine the workability of fresh concrete. Specifies a method for determining the slump of fresh concrete both in the laboratory and in the field. Test procedure the original mini slump cone test procedure uses a 600 gram sample. Hence, an accurate prediction of this property is a practical need of construction engineers. When a truck mixer reaches the checkpoint, the quality engineer should check the delivery note to ensure that the concrete delivered is in compliance with the concrete grade required for the concrete element to be cast. Slump cone sets slump cone set the portable slump test set includes all tools necessary to conduct a slump test on a sample of freshly mixed concrete. Pdf on dec 5, 2014, bhupesh mulik and others published mini slump test procedure find, read and cite all the research you need on researchgate. The unique base design allows all components to be combined into a onepiece unit. The slump test result is a measure of the behavior of a compacted inverted cone of concrete under the action of gravity.
It is not applicable when the maximum size of aggregate is greater than 40 mm. American society for testing and materials astm standards are astm c 143 or astm c143m. When the slump test is carried out, following are the shape of the concrete slump that can be observed. It is used conveniently as a control test and gives an indication of the uniformity of concrete from batch to batch. The slump test is a practical means of measuring the workability. Procedure of slump flow test on self compacting concrete. What are the difference between tender and contract documents. Use of the slump test over the straight leg raise test. More is the slump value more will be the workability.
Standard test method for slump flow of selfconsolidating concrete 1. Slump test is the most commonly used method of measuring consistency of concrete which can be employed either in laboratory or at site of work. The slump test indicates the behavior of a compacted concrete cone under the action of gravitational forces. The unit includes sampling and slump testing to a set range. When the mortars and concretes for which the final slump was less than 100 mm are excluded, the measured slump times range from 0. We usually perform slump test on site and lab due its ease and results. Concrete having a different mix m15 or m20 etc with the suitable watercement ratio and can be prepared at the site or casting the 6 cubes after conducting the slump test. The slump cone is filled with fresh concrete in layers, tamping between each to remove voids. Slump test procedure and sheet concrete building engineering. Now place the mould cone on the metallic steel plate or on any smooth surface. Illinois test procedures for other materials may be included.
Concrete slump test procedure applications, types, uses. It gives quick result about the workability of concrete. Reproducible minislump test procedure for measuring the yield stress of cementitious pastes article pdf available in materials and structures 506 december 2017 with 1,073 reads. The base is 200 mm 8in in diameter and it has a smaller opening at the top of 100 mm 4 in. Examination and treatment the slump test is becoming more widely accepted as an examination and treatment procedure for all levels of the vertebral column. The attached handle can be rotated above the specimen and used as a guide to measure the slump. Standard test method for slump flow of selfconsolidating concrete c 1611 8. Cpccco3053a slump test concrete date this document was generated. Commence the slump test as soon as possible after sampling of concrete as per standard procedure described in chapter 2.
Slump test is the most commonly used test of measuring workability of concrete. The sensitivity and specificity of the slump and straight leg raised tests in patients with lumbar disc herniation. No matter, slump test is a leader among the above tests. It measures the consistency or the wetness of concrete which then gives an idea about the workability condition of concrete mix. The slump test is perhaps the most widely used because of the simplicity of the apparatus required and the test procedure. The test adds the parameter of time to the standard slump test in. Astm c1611c1611m18 standard test method for slump flow of. Acceptance testing and criteria are give in section 8.
A number of refinements that modify hip and ankle position has been added to the basic slump test procedure, but no. Astm c1611c1611m18 standard test method for slump flow. The method is applicable to plastic and cohesive concrete. Slump cone, scale for measurement, temping rod steel procedure of concrete slump test. The water content was adjusted to compensate for the dry gravel and sand used in the lab.
The concrete slump test is an onthespot test to determine the consistency as well as workability of fresh concrete. Concrete slump test experiment procedure civilology. In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to know and speak the laws that govern them. The slump operation shall be completed in a maximum elapsed time of 2 12 minutes. It is then held firmly in place during filling of concrete by the operator standing on two foot pieces. The common factor among sources is the reproduction of pain as tension is applied to the dura during testing. Procedure to determine workability of fresh concrete by slump test.
Fill the cone with concrete in four layers each with an approximate height of 14th of the. Acceptance testing and criteria for ready mixed concrete. On removing the cone, the slump is measured photo sequence 1. This research proposes a machine learning model for predicting. The sampling and the test is performed under the following rules and laws. Concrete slump test generally concrete slump value is used to find the workability, which indicates watercement ratio, but there are various factors. It can be employed either in laboratory or at site of work. Concrete slump test procedure ppt presentation summary. The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or abrams cone, that is open at both ends and has attached handles. Pdf reproducible minislump test procedure for measuring the. Results of these tests were compared to the mri results of the 75 patients involved in this study. Concrete slump is generally known to affect the consistency, flowability, pumpability, compactibility, and harshness of a concrete mix. Pdf reproducible minislump test procedure for measuring.
The modified slump test as described was performed on all of the mixtures and the partial slump times which will hereafter be called the slump times are given in the tables in appendix ivvi. Describes also apparatus, procedure, expression of results, and. After mixing the concrete, the slump test was then carried out. The measured slump must be within a set range, or tolerance, from the target slump. The cone was then removed and the slump was measured using a tamping rod and a metre rule as shown in. The mould is placed on a flat moist nonabsorb surface with the smaller opening at the top. Mar 09, 2017 the slump test is perhaps the most widely used because of the simplicity of the apparatus required and the test procedure. Collect a sample of concrete to perform the slum test. Here are the steps to do the slump test of concrete.
Concrete workability, quantified by concrete slump, is an important property of a concrete mixture. Concrete slump test for workability procedure and results. The slump test is a neural tension test used to detect altered neurodynamics or neural tissue sensitivity. The remaining paste is remixed at 15,000 rpm for 1. Empty the sample from the container onto the sampling try. Standard test method for the slump of hydraulic cement concrete. Fill cone full by volume and rod 25 times with 58inchdi ameter x 24inch long hemispherical tip steel tamping rod. In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to. The slump test is described differently among sources. The aashto standard test procedure reports the percentage of material finer than the no. The result of this slump test value should be recorded in millimeters.
A small variation in slump caused by improper procedure or equipment,may cause the rejection of an entire load of concrete. A sample is poured into a mini slump cone, rodded, struck off, and lifted at 2 minutes. The flow table test procedure does not conform with astm standard and is as follows. If this test is being carried out in the field, the sample mixed concrete shall be obtained. Thoroughly mix the sample by shovelling to form a cone on the. This method of test specifies the procedure to be adopted. The slump test the slump test is done to make sure a concrete mix is workable. The slump plate should be clean, firm, level and nonabsorbent. Tests on concrete concrete slump test, compression test for. After the material is introduced into the water, the mixing speed in increased from 1,200 rpm to 15,000 rpm for 1 minute. During slump testing, terminal knee extension is assessed for signs of restricted range of motion rom, which may indicate impaired neural tissue mobility. Slump flow test on self compacting concrete for workability.
Concrete is placed into a cylindrical steel mold with an inner diameter of 36 mm. An appraisal was made on a prospective casecontrol study by majlesi j, togay h, unalan h, and toprak s, which determined the sensitivity and specificity of the slump test and straight leg raise test. Roll the drum for a certain time to completely mix the concrete inside. Pdf the minislump test is a fast, inexpensive and widely adopted method for evaluating the workability of fresh cementitious pastes. Thoroughly clean the inner surface of frustum cone and it should be free from moisture content. Slump plate 500 mm x 500 mm procedure of slump test for concrete. The technique depicted below is adapted from mark dutton. Definition slump is the gap between the mold top after removal and the top of result concrete. Hard copies prior to january 1, 2015 are controlled. This test plays a vital role in ensuring immediate concrete quality in a construction project. Moisten the base plate and inside of slump cone, place base plate on level stable ground and the slump cone centrally on the base plate and hold down firmly. The concrete is levelled off with the top of the cone. Fill the container in three equal layers at approximately 258 in 67 mm and 618.
1438 1247 282 315 972 1283 40 778 1285 1056 1024 1512 159 441 1346 891 418 1013 1206 1388 349 752 807 948 890 1432 284 13 1353 806 195 509 569 476 1200 953 82 970 205 315 400 1042 615 783